A gas heater pilot light is a small flame that burns continuously to ignite the main burner when your thermostat calls for heat. Think of it as the starter for your heating system. When this tiny flame goes out, your heater stops working entirely—no heat reaches your home, even though gas is available to the system.
Learn About Paying Your FGUA Bill Online →
Several common reasons cause pilot lights to extinguish. The most frequent culprit is a dirty or bent thermocouple, which is a safety device that detects whether the pilot flame is burning. If the thermocouple gets coated with dust or soot, or if it shifts slightly out of position, it may incorrectly signal that no flame is present, even when one exists. This triggers a safety mechanism that shuts off gas flow to prevent dangerous leaks.
A draft or air current flowing across the pilot opening can physically blow out the flame. This sometimes happens in basements, crawl spaces, or utility closets where heaters are located near doors, windows, or ventilation ducts. In other cases, a pilot that's set too low produces a weak flame that struggles to stay lit, particularly when air movement is present.
Occasionally, the pilot assembly itself needs cleaning. Carbon buildup inside the pilot tube or around the burner opening restricts gas flow and disrupts the flame. Over time, minerals in the gas supply and combustion byproducts accumulate in these tight spaces. A heater that's more than 10 years old is more likely to experience pilot problems from this type of deterioration.
Practical takeaway: Before you attempt to relight your pilot, understand that a pilot light going out repeatedly—more than once or twice per season—usually signals a maintenance issue beyond simple relighting. Jotting down how often your pilot extinguishes helps you decide whether to call a professional or try relighting yourself.
To relight your pilot, you first need to find it. The pilot light sits inside your heater unit, typically visible through a small window or access panel on the front of the furnace or water heater. On most residential gas heaters manufactured in the last 20 years, you'll see a small metal tube with a tiny nozzle at the end—this is where the pilot flame burns. The pilot compartment is usually positioned near the main burner assembly, often recessed slightly into the heater cabinet.
Free Guide to Pay by Plate Illinois Billing →
Next to the pilot assembly, you'll notice the control valve—a cylindrical component with a knob or dial. This valve regulates both pilot and main burner gas flow. Most modern control valves have three marked positions: OFF, PILOT, and ON (or sometimes labeled as different heat settings). Some older heaters use a valve with just two positions. Understanding this valve is crucial because relighting always starts by moving it to the PILOT position.
On the control valve, you'll typically find a small red button labeled "IGNITION" or simply marked as a push button. This manual ignition button lets you light the pilot without needing a match or lighter. Some heaters have a slightly different design where you'll need to use an external flame source instead. Check your heater's documentation or look for any labels printed directly on the unit.
The thermocouple appears as a thin copper or steel tube running from the pilot assembly upward into the valve body. You don't need to touch it during relighting, but recognizing it helps you understand how the system works. The thermocouple tip sits directly in the pilot flame's hottest zone. When the flame heats this tip, it generates a small electrical signal that tells the valve "the pilot is lit, it's safe to send gas to the main burner."
Practical takeaway: Before touching anything, take a photo of your valve and pilot assembly with your phone. This reference helps you remember what you saw if you need to describe the situation to a technician later, and it documents the valve's original settings if you accidentally move them.
Relighting a pilot light is generally a safe procedure when done correctly, but gas appliances demand respect. Gas itself is colorless and odorless, so utility companies add a chemical marker that smells distinctly like rotten eggs or sulfur. If you detect this smell near your heater, do not attempt to relight the pilot. Instead, open windows immediately to ventilate your home, leave the house, and call your gas company's emergency line from outside. A gas leak requires professional attention.
Free Guide to Mold Removal Methods for Walls →
Before beginning any relighting attempt, turn off the heater completely by moving the control valve to the OFF position. This halts all gas flow to both the pilot and main burner. Wait at least five minutes before proceeding. This waiting period allows any residual gas near the pilot to dissipate safely. Skipping this step risks creating a pocket of gas that ignites unexpectedly when you introduce a flame.
If you smell gas or hear a hissing sound while attempting to relight, stop immediately. Move the valve back to OFF, step away from the heater, and open nearby windows. Wait 15 to 20 minutes, then try again from the beginning. If the hissing or smell persists, do not continue. Your heater has a gas leak, possibly at a connection point or within the valve itself, which requires a licensed technician to repair safely.
Know when to call a professional instead of persisting. If your pilot light goes out during the first attempt to relight it (meaning you successfully light it, but it extinguishes immediately), this usually indicates a thermocouple issue or a deeper mechanical problem. Similarly, if you've attempted to relight the pilot three separate times without success, further attempts are unlikely to work. Some issues—such as a faulty ignition button, a cracked control valve, or carbon buildup inside the burner—cannot be fixed by simply relighting. A heating technician has specialized tools and experience to diagnose these problems correctly.
Practical takeaway: Keep your gas company's phone number posted near your heater or programmed in your phone. Knowing immediately what to do if something goes wrong prevents panic and ensures you respond correctly to any gas-related concerns.
Begin by turning the control valve to the OFF position and waiting five minutes for any residual gas to clear. This is your mandatory safety step every single time. During this wait, locate a long-reach lighter or long fireplace match. A regular handheld lighter works, but long-reach versions keep your hand farther from the pilot area. Some heaters have an electronic ignition button that eliminates the need for an external flame source, so check your valve first.
How to Delete Your Fitbit Account Guide →
After the five-minute waiting period, turn the control valve to the PILOT position. You should hear a faint clicking sound if your heater has electronic ignition. Hold this position for several seconds. If you're using a lighter or match instead of an ignition button, now is when you'll prepare your flame source and approach the pilot opening.
If your heater has a push-button igniter on the valve, press and hold it while simultaneously bringing a lit lighter or match near the pilot opening. The flame should ignite within a few seconds. Continue holding the button for 30 to 40 seconds after the pilot lights. This extended hold time allows the thermocouple to heat up sufficiently to generate its safety signal. If you release the button too early, the pilot may go out immediately because the thermocouple hasn't reached operating temperature yet.
Once the pilot flame appears stable and blue (not orange or yellow), slowly move your heat source away and watch the flame for several seconds. A properly lit pilot burns with a steady, bright blue flame about an inch tall. The flame should wrap slightly around the thermocouple tip. If the flame appears weak, yellowish, or flickers excessively, turn the valve back to OFF and wait before trying again.
After confirming the pilot is burning steadily, turn the control valve from PILOT to ON (or to your desired heat setting). You should hear the main burner ignite within 30 seconds, producing a larger flame and initiating heat production. If the main burner doesn't ignite or if the pilot extinguishes when you turn the valve to ON, move it back to PILOT and hold for another 40 seconds, then try the transition to ON again.
Practical takeaway: Write down the exact time you successfully relight
This guide is for general information only and is not medical, financial, legal, or other professional advice. For decisions specific to your situation, consult a qualified professional. See our Editorial Policy.